Inverter Manual: Jte

Maintain an ambient temperature between -10°C and 50°C. For altitudes above 1,000 meters, derate the output current by 1% for every 100 meters.

Mount the unit vertically with at least 150mm of clearance above/below and 50mm on the sides for heat dissipation. Jte Inverter Manual

Set the primary speed adjustment method (e.g., keypad, digital setting, or analog input). Confirm: Press ENTER after modifying any value. 4. Troubleshooting and Maintenance Maintain an ambient temperature between -10°C and 50°C

Connect exclusively to the P+ and PB terminals. Jte Inverter Manual

For safety, the inverter and motor must be well-grounded, as leakage current may exceed 3.5mA. 2. Wiring and Technical Specifications

Set to 0 for control panel operation or 1 for external terminal control.